Independent Owner's Engineer — Offshore Wind

Nobody owns your
SCADA integration
layer. We do.

From day one of design to final commissioning handover. No vendor to protect. No platform to sell. Just independent technical oversight of your SCADA scope.

IEC 61850IEC 62443IEC 61400-25HVDCNIS2
Currently active — Hornsea 3 HVDC
15+
Years offshore wind
10+
Major projects
10+ GW
Capacity delivered
6
Developer clients
Hornsea 3 HVDC
Ørsted
Active
Norfolk Boreas & Vanguard
Vattenfall / RWE
Done
Veja Mate · Merkur · Baltic Eagle
ENGIE Fabricom
Done
View all projects →
The problem we solve

Offshore SCADA gaps are invisible
until delivery is at risk

The challenge
No single owner of the integration layer
Interface failures discovered too late
Vendor interests misaligned with yours
Commissioning pressure creates reactive decisions
Signal conflicts found during SAT, not FEED
Our solution
One independent voice owning the integration layer
Interface management from FEED through commissioning
No vendor, no platform — your interests only
IEC 61850, IEC 62443, and IEC 61400-25 expertise
Vendor-neutral signal register and conflict detection
What we do

Where Scada Fortis creates value

01

Owner's Engineer

Independent technical oversight of your SCADA and telecom scope — protecting developer interests from FEED through commissioning handover.

Learn more →
02

SCADA Engineering

Architecture review, signal register ownership, interface matrix management, and vendor-neutral specification authoring.

Learn more →
03

Commissioning

FAT, SAT and SIT coordination, ITP witness, punch list governance, and commissioning documentation across all SCADA and telecom systems.

Learn more →
04

Interface Management

Structured management of technical interfaces between SCADA, protection, telecom, and third-party systems — catching conflicts before they become delays.

Learn more →
05

OT Cybersecurity

IEC 62443 zone and conduit design, OT network segmentation, NIS2 compliance review, and cybersecurity scope ownership for offshore OT environments.

Learn more →
06

Telecom & Networks

Offshore fibre, MPLS, PAGA, private LTE and VSAT satellite backup design and commissioning. OT network architecture and vendor coordination.

Learn more →
Free tool

FORTIS CONNECT
Signal Mapper

Free browser tool to detect signal conflicts between two SCADA interfaces — missing signals, type mismatches, direction conflicts, and IEC 61850 logical node violations. No upload, no login, runs entirely in your browser.

Try the free tool →
Missing signal detection
Signals present on one side but absent on the other
Type mismatch detection
Boolean declared Analog — or vice versa
Direction conflict detection
Both sides declaring OUT with no consumer
IEC 61850 LN validation
DA compatibility check against 61850-7-4
Per-WTG aggregation
Interface readiness score per turbine
Start the conversation

Bring independent SCADA oversight
into your offshore wind project

SCADA and telecom problems found in FEED cost a fraction of what they cost during commissioning. Bring us in early — before the interfaces are locked and the pressure is on.